nernst
  
         What about potassium ???    K*



 
 
 
 
 
 
 
 
 
 
 
 
 
 
 






Nernst Potential for Potassium...   

    E (mv) = +/- 62 Lg10 [ Co ]
                                     [ Ci ]

                    [ Co ] =  1.0 mM  K  and  [ Ci ] = 7.0 mM

    
    E =  + 62  Lg10  1.0/7.0 

       =  + 62  Lg10   0.1428

       =  + 62  -(0.8453)

    E- 52.4 mV is the value of the calculated Nernst Potential

          since the measured bioelectric potential inside the cell is 
       + 10 mV then, K does NOT move passively across this
          membrane, and therefore
K must move ACTIVELY.
  back

 

 

   

K Nernst